You are here: home    Products    Storage    Fiber-to-SATA RAID Subsystems    4U Infortrend 4G FC to SATA...

SKU# A24F-R2430

4U Infortrend 4G FC to SATAII 24 bay RAID Subsystem

THE A24F-R2430 SAN-READY SUBSYSTEM COMBINES THE COST-EFFECTIVE SATA DRIVES IN A HIGH AVAILABILITY 4G FC ARRAY. IT MANAGERS WILL FIND IT IS AN EASY-TO-USE AND EASY TO MAINTAIN STORAGE SOLUTION FOR THEIR DAS, FIBRE CHANNEL SAN AND CLUSTERED SERVERS OR ANY A

Feel free to ask us for a quote on this product.

4U Infortrend 4G FC to SATAII 24 bay RAID Subsystem
4U Infortrend 4G FC to SATAII 24 bay RAID Subsystem
4U Infortrend 4G FC to SATAII 24 bay RAID Subsystem

4U Infortrend 4G FC to SATAII 24 bay RAID Subsystem


Infortrend A24F-R2430 4U FC to SATA-II RAID subsystem 24 Bay


The A24F-R2430 SAN-ready subsystem combines the cost-effective SATA drives in a high availability 4G FC array. IT managers will find it is an easy-to-use and easy to maintain storage solution for their DAS, Fibre Channel SAN and clustered servers or any application requiring dedicated bandwidth

In addition to outstanding performance and dependability, the EonStor SATA line offers improvements in ergonomics and ease of use and provides compelling, cost-effective, state-of-the-art networked storage solutions.

Typical use
  • Disk-to-disk backup
  • Server-attached
  • Network data storage
  • Major industries such as medical imaging, security / CCTV, and digital media including video-on-demand stream editing and more.
Features and benefits
  • Ultra-high-density, 4U-profile, 24-bay enclosure
  • Single or dual-active redundant RAID controller
  • Two (2) 4G-FC host channels per RAID controller
  • Expansion via SFF-8470 SAS wide links
  • Designed for SATA-II (3Gbps) disk drives
  • Intelligent load-balancing internally & externally by the EonPath™ multipathing software
Infortrend Smart Technologies
Derived from a decade of experience in RAID storage design, Infortrend's innovative firmware delivers Smart technologies that provide enhanced storage solutions for every customer environment, from small organizations to large enterprises. These technologies enhance I/O processing, drive handling, and system management.
IOSmart
IOSmart allows for the flexible configuration of logical drives, logical volumes and logical partitions and ensures instant RAID availability via background logical drive initialization. Fibre loops' load balancing is provided within the subsystem. The firmware' s Adaptive Write Policy and Guaranteed Latency I/O algorithms improve write performance and ensure fast and continuous data flow.
DrvSmart
The DrvSmart utilities manage disk drive defects and help ensure data integrity. One of the main DrvSmart functions, Media Scan, retrieves data from degraded or damaged hard drives and handles low quality drives in both the degraded mode and during the rebuild process. Other DrvSmart features include disk cloning, drive roaming, SMART, transparent resetting of non-responsive hard drives, RAID parity update tracking and recovery.
SysSmart
SysSmart combines enclosure monitoring and firmware management capabilities in order to minimize the chance of down time caused by hardware failures. The SysSmart functions include the event-triggered cache flush and the various monitoring approaches combined with the powerful RAIDWatch manager. Component status, voltage and temperature readings, and system events are instantly revealed through the manager's graphical interface.

RAID Multiple arrays with Dedicated, Global, or Enclosure-specific hot spares
RAID levels supported; RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
ASIC400 backbone
Online expansion by;
Adding new drives
Copying and replacing drives with drives of larger capacity
Automatic background rebuild
Configurable stripe size and write policy per array
Intelligent drive handling;
In degraded mode; skips irreparable blocks to continue rebuild
In normal operation; data-block verification and repair
System components Redundant controller configuration provides full RAID functionalities
One (1) EonStor enhanced 4U enclosure
Two (2) RAID controller module
One (1) 256MB DDR RAM DIMM module (pre-installed on the controller modules)
Two (2) hot-swappable, redundant, 530W power supply units (PSUs)
Two (2) redundant, dual-fan cooling modules running in high/low speeds
One (1) optional BBU
Twentyfour(24) hot-swappable drive trays
Two (2) front handles
Host interface Four (4) FC-4G host channels with embedded bypass to eight (8) Fibre ports
Auto-negotiate FC-AL, point-to-point, or switched fabric
Concurrent I/O commands
Tagged command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Drive interface Twentyfour (24) hot-swappable 3Gbps SATA-II (3Gbps) drive trays that accommodate 1-inch pitch,
3.5-inch SATA-II (3Gbps) or SATA-I disk drives
Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
Management Firmware-embedded utility via LCD keypad or RS-232C port
Host-side SES emulation with pass-through to back-end SES emulation
VT-100 terminal emulation via RS-232C
Telnet access via onboard Ethernet port
10/100 BaseT Ethernet for out-of-band management
Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
Firmware-embedded Java-based RAIDWatch® manager;
Graphical user interface
Local/remote management; in-band or out-of-band via TCP/IP
Centralized management to monitor and administer multiple RAID units on one screen
Secure link over SSL
Configuration Client for easy access to the configuration utility screen
SNMP 2.0 MIBs with get and set commands
San Management Up to 1024 LUN's (if sufficiently large memory is used with the proper settings)
Indicators Onboard alarm
Module status LED indicators Two (2) per drive tray Three (3) per LCD panel Seven (7) per RAID controller module Two (2) per Ethernet port Two (2) per cooling module One (1) per power supply unit One (1) per BBU module Two (2) per FC port Module failure alert through I2C bus Event notifications sent over email, fax, LAN broadcast, SNMP traps, MSN messenger, SMS short messages System alerts through Java-based RAIDWatch manager
Dimensions Chassis without handles 445(W) x 174.4(H) x 498(D) mm (17.5 x 6.86 x 19.2 inches) Chassis with handles 482.6(W) x 174.4(H) x 514(D) mm (19 x 6.86 x 20 inches) Package 520(H) x 580(W) x 780(D) mm (20.5 x 22.8 x 30.7inches)
System weight (w/o drives) Net weight 38kg Gross weight 41kg